CQR FP3/RD Conventional Fire Alarm Manual Call Point, EN54-11, Red

£16.95

Availability: 95 in stock SKU: FP3/RD Category:

Description

FireBrand FP3/RD Conventional Manual Call Point – EN54-11 Certified with High Visibility LED & Selectable Monitoring Resistors

Professional Red Manual Call Point for Conventional Fire Alarm Systems with Dual Window Options & Integrated Monitoring

The FireBrand FP3/RD represents professional-grade manual call point technology engineered for conventional fire detection systems. This EN54-11 and CPR certified call point combines high-visibility LED status indication with selectable monitoring resistors (470Ω/680Ω), dual frangible and resettable window options supplied as standard, and optional transparent protective covers—delivering flexible, compliant fire alarm activation for commercial, industrial, and institutional applications. The user-friendly design, integrated test and reset functionality, and comprehensive certification make this call point an essential component of professional fire safety installations.

Product Overview

Designed for fire alarm installers, electrical contractors, facilities managers, and building safety professionals, the FireBrand FP3/RD manual call point functions as a critical human-initiated alarm activation device within conventional fire detection systems. The dual-element design—with both break-glass frangible and key-resettable elements supplied as standard—provides installation flexibility across diverse applications. The high-visibility LED, selectable end-of-line monitoring resistors, and optional protective cover deliver a comprehensive call point solution suitable for public buildings, commercial premises, educational institutions, healthcare facilities, and industrial environments requiring reliable manual fire alarm initiation.

Key Features & Benefits

Certified Compliance & Approval

  • EN54-11 Certified: European standard for manual call points in fire detection systems
  • CPR Approved: Construction Products Regulation compliance for EU/UK markets
  • Conventional System Compatibility: Designed for standard conventional fire alarm systems
  • Regulatory Assurance: Meets fire safety system component requirements
  • Professional Specification: Independently tested and certified performance
  • Building Control Acceptance: Suitable for regulatory approval submissions

Dual Window Element System

  • Frangible Glass Element: Traditional break-glass activation supplied as standard
  • Resettable Plastic Element: Key-operated resettable element included for reusable operation
  • Application Flexibility: Choose element type based on installation requirements
  • Cost-Effective Operation: Resettable element reduces replacement costs after testing
  • Easy Element Change: Straightforward swapping between element types
  • Professional Versatility: Single call point suits diverse installation scenarios

High Visibility LED Indication

  • Activation Confirmation: LED illuminates upon call point activation
  • Visual Status Indication: Clear confirmation of operated call point
  • Fire Location Identification: Illuminated LED aids rapid identification of activated device
  • System Diagnostics: Supports fire alarm system testing and verification
  • Reduced Response Time: Visual indication accelerates emergency response
  • Professional Standard: Integrated LED as standard feature

Selectable Monitoring Resistors

  • 470Ω Resistor Option: Standard end-of-line monitoring value
  • 680Ω Resistor Option: Alternative monitoring value for diverse panel compatibility
  • Jumper Selection: Simple field-configurable resistor selection
  • Panel Compatibility: Works with various conventional fire alarm control panels
  • Installation Flexibility: Adapt to existing system monitoring requirements
  • User-Friendly Configuration: No specialist tools or components required

Protective Cover Options

  • Transparent Cover Available: Optional lift-up cover prevents accidental activation
  • Accidental Operation Prevention: Cover deters false alarms from inadvertent contact
  • Visual Deterrent: Clear cover maintains call point visibility while providing protection
  • Public Area Suitability: Ideal for high-traffic locations with accidental activation risk
  • Professional Integration: Cover integrates with call point design
  • Flexible Specification: Choose with or without cover based on application

Key-Resettable Operation

  • Resettable Element Included: No replacement parts required after testing
  • Simple Reset Procedure: Key operation returns call point to normal state
  • Reduced Maintenance Costs: Reusable element eliminates replacement expenses
  • Testing Convenience: Facilitates routine fire alarm system testing
  • Professional Efficiency: Streamlined maintenance and testing workflow
  • Inventory Reduction: No need to stock replacement glass elements for resettable use

Conventional System Integration

  • Normally Open Contact: Standard conventional fire alarm circuit configuration
  • Monitoring Resistor Compatibility: 470Ω or 680Ω EOL resistor selection
  • Single Pole Operation: Standard electrical configuration for conventional systems
  • Universal Panel Compatibility: Works with major conventional fire alarm panels
  • Professional Installation: Compatible with standard fire alarm cabling
  • System Reliability: Proven performance in conventional fire detection networks

Technical Specifications

SpecificationDetail
ManufacturerFireBrand
Model NumberFP3/RD
Product TypeConventional manual call point
System CompatibilityConventional fire alarm systems
OperationSingle pole, normally open contact
Activation MethodFrangible glass (break-glass) or resettable plastic element
Elements SuppliedBoth glass and resettable elements included as standard
Reset MethodKey-operated (resettable element)
LED IndicatorHigh visibility activation LED (standard feature)
Monitoring Resistors470Ω and 680Ω (jumper selectable)
End-of-Line (EOL)Selectable 470Ω or 680Ω
Optional CoverTransparent lift-up protective cover available
ColorRed (standard fire alarm call point color)
CertificationEN54-11, CPR approved
Approval BodyThird-party tested and certified
Mounting TypeSurface wall-mounted
InstallationStandard electrical box mounting
ApplicationConventional fire detection and alarm systems
Suitable EnvironmentsCommercial, industrial, institutional, public buildings
Professional GradeFully certified fire alarm system component