CQR Natural Gas Detector 24V with Relay Output

£54.95

Availability: 39 in stock SKU: CQR-983NG Category:

Description

24V Conventional Natural Gas Detector – Professional Leak Detection with Relay Output & Base

Advanced Gas Sensing Technology for Residential & Commercial Natural Gas Safety Systems

The 24V conventional natural gas detector represents professional-grade gas leak detection engineered for rapid threat identification and emergency response. This sophisticated detector combines advanced sensor technology with integrated relay output capability, enabling seamless integration into comprehensive safety and alarm systems. The sensitivity-tiered detection (100-400 ppm across variable response times), audible alarm output (70dB siren), and dual-voltage compatibility (12/24VDC) deliver dependable gas leak detection suitable for residential, commercial, and industrial applications requiring reliable natural gas monitoring and emergency notification.

Product Overview

Designed for safety professionals, facility managers, building contractors, and security system integrators, the 24V natural gas detector functions as a critical safety infrastructure component. The advanced gas-sensing technology, integrated relay switching, and comprehensive monitoring capability transform passive gas leak risk into active detection and emergency response. This professional-grade solution delivers rapid threat identification and automatic emergency notification—protecting occupants and infrastructure from the hazards of natural gas leaks.

Key Features & Benefits

Advanced Natural Gas Detection

  • Dedicated Gas Sensing: Specialized detector for natural gas (methane) detection
  • Multiple Sensitivity Levels: Tiered detection across various concentration ranges
  • Rapid Response Capability: Quick activation at elevated gas concentrations
  • Professional Sensitivity: 100-400 ppm detection across specified timeframes
  • Reliable Detection: Proven gas-sensing technology
  • Safety Critical: Essential for natural gas safety systems

Sensitivity-Tiered Detection System

  • 100 ppm Detection: Detects within 90 minutes at lower concentrations
  • 200 ppm Detection: Identifies within 35 minutes at moderate concentrations
  • 400 ppm Detection: Rapid response within 15 minutes at high concentrations
  • Progressive Response: Earlier detection at higher concentration levels
  • Professional Specification: Tiered sensitivity meets industry standards
  • Comprehensive Coverage: Covers full range of hazardous gas levels

Integrated Relay Output

  • Dual-Voltage Compatibility: Works with 12VDC or 24VDC systems
  • Relay Switching: Electrical contact closure upon gas detection
  • System Integration: Seamless connection to alarm and safety systems
  • Fail-Safe Design: Reliable relay operation during emergency
  • Flexible Configuration: Compatible with diverse control architectures
  • Professional Grade: Commercial-quality switching capability

Audible Alarm Capability

  • 70dB Siren Output: Loud alarm signal for emergency notification
  • High-Decibel Alert: Ensures occupant awareness during gas leak
  • Clear Warning Signal: Distinct sound pattern for emergency identification
  • Audible Range: Suitable for residential and commercial spaces
  • Emergency Communication: Clear acoustic notification of danger
  • Life Safety: Essential audible alert for occupant protection

LED Status Indicator

  • Visual Confirmation: LED display shows operational status
  • Power Indication: Confirms unit is powered and operational
  • Alarm Activation: Visual signal when gas detected
  • Maintenance Support: Status indication assists diagnostics
  • Professional Feedback: Clear visibility of system operation
  • User Awareness: Immediate visual confirmation of alert condition

Professional Electrical Architecture

  • 12/24VDC Operation: Dual-voltage compatibility for flexible installation
  • 4-Pin Connection: Standard terminal configuration
  • Low Power Consumption: 2W operating power requirement
  • Efficient Operation: Minimal electrical load on power supply
  • Professional Compatibility: Works with standard control systems
  • Reliable Power Management: Stable operation across voltage range

Technical Specifications

SpecificationDetail
Product TypeConventional natural gas detector
Detection TargetNatural gas (methane) leaks
Detector TechnologyAdvanced gas-sensing element
Operating Voltage12VDC or 24VDC (dual-voltage)
Voltage FlexibilityCompatible with 12V and 24V systems
Power Consumption2W operating power
Current DrawLow-current design for efficient operation
Sensitivity Level 1100 ppm within 90 minutes
Sensitivity Level 2200 ppm within 35 minutes
Sensitivity Level 3400 ppm within 15 minutes
Detection Range100-400 ppm natural gas
Response TimeVaries 15-90 minutes by concentration
Relay OutputElectrical contact closure upon detection
Relay ConfigurationSwitching contact for system integration
Connection Type4-pin terminal configuration
Terminal SystemScrew-down or connector terminals
LED IndicatorMulti-function status display
Siren Sound Level70 dB audible alarm output
Alarm TypeIntegrated siren with relay activation
Operating Temperature-10°C to +50°C range
Temperature ResilienceWide operating range for diverse climates
Unit Weight0.130 kg (lightweight)
Base IncludedMounting base supplied with detector
Installation TypeSurface-mount with supplied base
Professional GradeSuitable for residential and commercial use
Safety StandardGas detection equipment specification