



Notifier XP6-MA Six-Zone Addressable Interface Module – 2-Wire Zone Control
£243.83
The Notifier XP6-MA provides six addressable initiating device circuits for interfacing conventional two-wire detection zones with intelligent fire alarm control panels using FlashScan® or CLIP protocols.
- Description
- Additional information
- Technical Specification
Description
The Notifier XP6-MA Six-Zone Interface Module is a high-performance addressable device that enables intelligent fire alarm systems to monitor and control up to six zones of conventional two-wire smoke detectors. Designed for seamless integration with Notifier fire alarm control panels, the XP6-MA is ideal for retrofit projects and hybrid detection systems where legacy devices must be incorporated into an addressable system.
Each XP6-MA module operates using a common Signaling Line Circuit (SLC) input while supporting independent operation for each of the six initiating device circuits (IDCs). These IDCs can be configured as six Class B (Style B) circuits or three Class A (Style D) circuits, offering deployment flexibility for various wiring environments.
Equipped with rotary address switches and individual status LEDs for each circuit, the XP6-MA ensures quick setup, easy troubleshooting, and real-time feedback. It supports both FlashScan® and CLIP communication protocols, ensuring compatibility with a wide range of Notifier systems.
Key Features:
- Supports six Class B or three Class A two-wire detection zones
- Transmits real-time status: normal, alarm, or open fault
- Shares a common SLC input with individual zone supervision
- Built-in status indicators for each IDC
- Accepts 12 to 18 AWG wire via removable plug-in terminal blocks
- Up to two unused IDC addresses can be disabled if not needed
- Rotary address switches simplify device programming
- Fully compatible with FlashScan® and CLIP protocols
- Mountable in BB-XP, BB-25, CHS-6, and CAB series enclosures
The Notifier XP6-MA is the ideal solution for hybrid fire alarm system configurations, offering reliable integration of legacy two-wire zones with modern addressable system architectures.
Additional information
Brand | NOTIFIER |
---|---|
Model No | XP6-MA |
Normal Operating Voltage | 15-32VDC |
Stand-By Current | 2.3 mA @ 24 V |
Alarm Current | 40 mA (assumes all six LEDs solid on) |
Temperature Range | 32ºF to 120ºF ( 0ºC to 49ºC |
Humidity | 10 to 93% Non-condensing |
Dimensions | 6.8˝H x 5.8˝W x 1.25˝D |
Accessories | CHS-6 Chassis; BB-25 Cabinet; BB-XP Cabinet; CAB-4 Series Cabinets; CAB-3 Series Cabinets |
Wire Gauge | 12-18 AWG |
Maximum IDC Wiring Resistance | 25 Ohms |
External Power Supply Voltage | Regulated 24 VDC |
Ripple Voltage | 0.1 volts RMS maximum |
IDC (supervised and power limited) | |
DC Voltage | 18-28 volts power limited |
Frequency | DC |
Alarm Current | 90mA per circuit |
Standby Current 6 circuits | 42mA Maximum @18 VDC 56mA Maximum @24 VDC 66mA Maximum @28 VDC |

Notifier XP6-MA Six-Zone Addressable Interface Module – 2-Wire Zone Control
£243.83